Panel load in minutes
NEC 220.82 optional method: total load, amps, percent of service and spare capacity, with what the charger adds.
The on-site calculator for Level 2 EV charger installs: NEC 220.82 panel load, breaker and wire size, voltage drop and conduit fill, then a clean PDF quote for your customer.


Why EV Charger Calc
Stop juggling a code book, a spreadsheet and a quote template.

NEC 220.82 optional method: total load, amps, percent of service and spare capacity, with what the charger adds.

125% continuous load, the next standard breaker, copper or aluminum at 60 or 75 °C, and voltage drop for the run.

Turn the numbers into a branded PDF quote with your logo, line items and price list, before you leave.
How it works
Enter the service size and the house loads; see if the charger fits or needs load management.
Pick the charger amps and the run length; get the breaker, conductor and voltage drop.
Add line items from your price list and share a clean PDF with the customer.
Free tools
NEC 2023 based. They run in your browser, no sign-up.
NEC 220.82 optional method for dwellings: will the charger fit on this service?
Open the toolCharger amps in, breaker and copper or aluminum conductor out, for THHN in conduit or NM-B cable.
Open the toolPercent drop for any run length, conductor size and charger load, single phase at 240, 208 or 120 V.
Open the toolInstall guides

A worked example on a 200 A service: general load, the first 10 kVA, heating and A/C, then the charger. How to tell whether the service can carry a Level 2 charger.

60 A breaker, 6 AWG copper THHN in conduit or 4 AWG NM-B: why the cable type changes the answer, plus aluminum, the ground, conduit size and long runs.

The 125% continuous load rule in one table, from 16 A to 80 A chargers, plus GFCI, the individual branch circuit rule, disconnects and adjustable chargers.
FAQ
Short answers about the app and the free tools.
Yes. The calculators are free on iPhone and Android. Pro adds PDF quotes, saved jobs and your company logo.
NEC 2023 by default, with the load calculation using the 220.82 optional method for dwellings. Always check local amendments with your AHJ.
Yes. Pick copper or aluminum and a 60 or 75 °C column; the result shows the smallest conductor that carries the load.
Yes. Build a quote from line items and your own price list, add your logo and share a clean PDF.
No. It is a calculator for professionals. Results are estimates; the installer and the AHJ have the final word.
Free on iPhone and Android. Load calcs, wire sizing and PDF quotes on site.